Laser equipment
Nd:YVO4 Pulsed UV laser
(INNGU LASER, Pulse 3553A)
-
Field: Manufacturing process
-
Power: 4 W
-
Wavelength: 355 nm (third harmonic generation)
-
Repetition rate: 30-80 kHz
-
Pulse width: 12-22 ns
-
Usage: 3 W UV nanosecond laser
CW fiber laser
(Raycus, RFL-C2000)
-
Field: Manufacturing process
-
Wavelength range: 1080 nm
-
Laser power: Max. 2 kW
-
Scan speed: Max. 100 mm/s
-
Usage: 2 kW fiber laser
Laser welding head
(Precitec, YW30)
-
Field: Manufacturing process
-
Wavelength range: 900 nm to 1090 nm
-
Laser power: Max. 6 kW
-
Operating temperature: 5 - 55 °C
-
Focusing lens: 100,125,150,200,250,300 mm
-
Usage: 2 kW fiber laser
Pulse fiber laser
(Raycus, RFL-P100MX)
-
Field: Manufacturing process
-
Pulse duration: 350 ns
-
Repetition frequency: 66 kHz
-
Average power: 100 W
Laser welding head
(Raytools, BW210)
-
Field: Manufacturing process
-
Wavelength range: 900 nm to 1090 nm
-
Power level: laser power < 1.5 kW
-
Protective windows: D27.9 * 4.1mm
-
Focusing lens: D30 F250
-
collimating lens: D30 F100
-
CCD: 8 Mega pixel
HeNe laser
(Thorlabs, HNL050RB)
-
Field: Collimating lens alignment
-
Optical power: 5 mW
-
Emission wavelength: 632.8 nm
-
Emission range: Visible & NIR
-
Beam diameter: 0.81 mm
-
Source material: HeNe
-
Spatial Mode/Shape: TEM00
Experiment & Analysis Tools
Optical microscope
(OLYMPUS, BH2-UMA)
-
Field: Measurement / Analysis
-
Magnification: 25X, 50X, 100X, 200X
-
Focal length: Manual focus
-
Usage: 2.5X to 20X magnification observable microscope with manual focus
Digital microscope
(Dino-Lite, AM4515 Series)
-
Field: Measurement / Analysis
-
Magnification: 700-900X
-
Focal length: Manual focus
-
Pixels: 1280 x 1024
-
Resolutions: 30FPS
-
Usage: 700 to 900X magnification observable microscope with manual focus
Laser power meter
(Laserpoint, PLUS 2)
-
Field: Measurement / Analysis
-
Magnification: 100 nW - 10 kW (power mode)
-
Dimensions: H 170 x W 100 x D 36-50 (mm)
-
Resolutions: 0.01 % - 0.1 % of Full scale
-
Usage: Measure the actual laser power
Pyrometer
(OMEGA, OS758-LS)
-
Field: Measurement / Analysis
-
Wide Measurement Range: Infrared up to 1600 °C
-
Narrow FOV, Distance to Spot Ratio of 60:1
-
Resolutions: 0.1°C/0.1°F at 83.2 to 999.9 (°C/°F), otherwise 1°C/1°F
-
Usage: Temperature measurement
Thermocouple Digital Thermometer
(OMEGA, HHC210)
-
Field: Measurement / Analysis
-
Wide Measurement Range: -200 ~1372 °C
-
Resolving power: 0.1°C : -100 ~ 1372 °C
-
Operating temperature: 0 ~ 50°C
-
Size: 24.7 X 50.9 X 132.9 mm
-
Weight: 148 g
-
Usage: Temperature measurement
Si Amplified Fixed Gain Detector
(Thorlabs, PDA10A2)
-
Field: Measurement / Analysis
-
Active area: Ø1 (0.8mm^2)
-
Operating temperature: 10 ~ 50 °C
-
Wavelength Range: 200 to 1100 nm
-
Peak Wavelength: 730 nm
-
Usage: Detect the light signal in the UV to the NIR wavelength range
Digital multimeter
(Fluke 17B+)
-
Field: Measurement
-
Capacitance: 1000 uF
-
AC, DC to 10 A
-
Max. voltage between the terminal and the ground: 1000 V
-
Usage: Measure the ohm/cap
Digital Stirring Hot Plates
(Corning, PC-420D)
-
Field: Sample preparation
-
Temperature range: 5 ~550 °C
-
Top plate size: 12.7 X 17.8 cm
-
Dimensions: 10.8 X 19.7 X 28 cm
-
Usage: Heating the specimen
Transformer
(SV-3022 1KVA 220V)
-
Field: Measurement
-
Rated output voltage range: 0 V- 240 V
-
Efficiency: 95 %
-
Rated capacity: 1KVA
-
Rated current: 4.2 A
-
Usage: Modulating the output voltage